Technical Data
|
Model |
G29DV |
G38DV |
G57DV |
G81DV |
|
Fuel Supply / GB |
Propane / l3 |
Propane / l3 |
Propane / l3 |
Propane / l3 |
|
Gas Pressure |
1.5 bar |
1.5 bar |
1.5 bar |
1.5 bar |
|
Gas Consumption Min/Max |
1.4 / 2.0 kg/h |
1.8 / 2.6 kg/h |
2.9 / 4.1 kg/h |
3.9 / 5.6 kg/h |
|
Capacity (Kw / Btu/h) |
29 / 100,000 |
38 / 132,000 |
57 / 200,000 |
81 / 270,000 |
|
Air Flow |
800 m³/hr |
900 m³/hr |
2100 m³/hr |
2100 m³/hr |
|
Electricity Supply |
(110)240/1/50 (V1)V/Ø/Hz |
(110)240/1/50 (V1)V/Ø/Hz |
(110)240/1/50 (V1)V/Ø/Hz |
(110)240/1/50 (V1)V/Ø/Hz |
|
Motor W/(A1)A RPM |
100/(1.5)0.75 1300 |
100/(1.5)0.75 1300 |
150/(2.0)1.0 2800 |
150/(2.0)1.0 2800 |
|
Limit Thermostat |
100±5°C |
100±5°C |
100±5°C |
100±5°C |
|
Minimum Ventilation |
625cm³ |
825cm³ |
1250cm³ |
1750cm³ |
|
Minimum Room Volume |
250m³ |
330m³ |
500m³ |
700m³ |
|
Jet Size |
1.15mm |
1.25mm |
1.5mm |
1.6mm |
|
Weight |
15Kg |
16.4Kg |
28Kg |
34Kg |
|
Dimensions L x W x H |
670 x 330 x 520mm |
730 x 330 x 520mm |
950 x 540 x 530mm |
1050 x 540 x 530mm |
For Further information on our Lgp Fan Forced Industrial Portable Heaters, or any similar products please contact us.