Waste Oil Heaters - SB Range with Automatic Ignition



Dont't throw away that used oil

Installation of Waste Oil Heaters

The positioning of Waste Oil Heaters in the workshop must take into account the following factors: a) power supply 220/240 volt (SB40/60) 400 V + N (SB80/110)

b) Flue pipe installation

c) Air supply to main ventilator

d) Connection to a compressed air supply.

e) Access to “Day” fuel tank

Control Thermostat and Waste Oil Heaters

This multifunctional thermostat ensures that the main fan only starts after the combustion chamber has been sufficiently heated. Therefore, there is no cold air blown before heater operation.

Multi Fuel Capability

These Waste Oil Heaters operate efficiently on a general mixture of used oil. Alternatively they can be run on diesel oil, or heating oil only. The air pressure to the burner has to be adjusted. Transformer oil, petro chemical based oil, or used cutting and grinding oil must NOT be used.

Combustion Control

The burner is equipped with a photocell that continuously monitors the flame.

In case of ignition failure or poor combustion, lack of a flame or partly blocked nozzle, the photocell stops the burner.

Waste Oil Heaters Built In Room Thermostat

This thermostat enables automatic operation of the heater in order to obtain the desired room temperature and on a low position is extremely useful for overnight frost protection.

Waste Oil Heaters are supplied with a basic room thermostat. An optional digital thermostat/timer control is available at an additional cost.

Indicator Lights on Waste Oil Heaters

Waste Oil Heaters have the following lights to show you:

1 and 2 are positioned on the front panel of the heater. 3 is positioned on the burner control box on top of the burner.

Service and Maintenance of Waste Oil Heaters

The design of Waste Oil Heaters ensures a minimum of necessary service and the service functions can be undertaken by the owner without special tools. The complete burner unit can be removed for any maintenance and service.

Overload Protection

Ventilation Only

In summertime the heater can be used for ventilation only.

Ventilation air flow rates:

SB40 – 3200m3/hr (1882cfm)

SB60 – 4100m3/hr (2412cfm)

SB80 – 6200m3/hr (3647cfm)

SB110 – 8100m3/hr (4765cfm)

 

Waste Oil Heaters Automatic Fuel Pre-heating (on used oil)

This system is activated when the heater is operated on used oil.

The pre-heater is then maintained at 70°C to 85°C controlled by a thermostat.

Non Return Valve

The non return valve in the fuel intake ensures that the burner cannot drain when it is not in operation.

Used Oil Compatibility with Waste Oil Heaters

The complete burner is fully automatic including the oil pre-heating system that ensures correct ignition and atomisation.

At required points, condensate drain valves are built into the system.

Flue Pipe

The standard flue kit consists of:-
1 x T Piece complete with Draught Stabiliser

4 x 1m lengths of Flue Piping

1 x Terminal Pipe

These items ensure the minimum height for efficient operation, ie 6 metres above ground level and 1 metre above the roof apex.

Supports
Wall bands are available to suit the Flues and for wall fixed installation should be located at 3 metre centres.

A Guy Wire fixing bracket is available to provide extra lateral support where the flue extends more than 1.5m above the last wall band, or for inter-connection with the roof flashing.

Roof penetrations
Flat and angled flashings of sheet aluminium are available to provide suitable weather cover where the flue penetrates a roof. Silicone rubber flashings are also available and highly recommended.

Storm collars of aluminium are also available and should be fitted to the pipe immediately above the flashings.

Terminations
To prevent leakage of rainwater into the pipe at joints which may be exposed above roof level, a change-over section is supplied in the flue kit. This section of pipe is provided with a male crimped coupling at each end and is designed for use where the flue passes through the roof: one end should be installed inside the building and one outside. Any subsequent components are installed inverted, i.e. with the male coupling upwards and fitted and secured in the normal way.

Rain caps are not permitted with used Waste Oil Heaters. The terminal pipe is designed to deflect rain water down the outer section.

NB. All lengths and fittings are fabricated from 0.55mm type 430 Stainless Steel.

A Detailed instruction and service manual is supplied with all our every Waste Oil Heaters

The environmental Protection Act 1990 Part 1.

On 1 st January 1991 the Environmental Protection Act came into force introducing new controls over air pollution and included provisions to cover used oil or recovered oil burners. Used oil heaters should not be operated until they have been registered with the relevant local authority. Application Forms are available from your local District or Borough Council. “Local Authorities are expected to determine applications for new appliances within 2 weeks of receipt.”

Individual Flue Components

Straight Lengths - Fixed straight lengths are available in two sizes:- 500mm, 1000mm and Adjustable.


Fixings


Change-Over Lengths (installed through roof)


Fittings


Flashings & Terminations



Part No.Description
Individual Flue Components for model SB40
41.900.821 Flue Pipe, 1 metre x150mm
41.900.822 Flue Pipe, ½ metre x 150mm
41.900.818 Flue Pipe Adjustable (540mm to 900mm x 150mm)
41.900.871 Terminal Pipe, 1 metre x 150mm
41.900.820 Changeover Pipe, 1 metre x 150mm
98.085.738 T-Piece & Draught Stabiliser & Condensation Trap & Adaptor
41.900.825 Flue Bend, 45° x 150 mm
41.900.834 Wall Band for 150mm Flue Stack (locate at 3m centres)
41.900.857 Guy Wire bracket 150mm
41.900.865 Angled Roof Flashing 150mm – Sheet Aluminium
41.900.866 Flat Roof Flashing 150mm – Sheet Aluminium
41.900.860 Storm Collar 150mm
   
Individual Flue Components for models SB60, 80 and 110
   
41.910.212 Flue Pipe, 1 metre x 200mm
41.910.215 Flue Pipe, ½ metre x 200mm
41.910.230 Flue Pipe Adjustable (540mm to 900mm x 200mm)
41.910.234 Terminal Pipe, 1 metre x200mm
41.910.214 Changeover Pipe, 1 metre x 200mm
41.910.229 Flue Bend, 45° x 200mm
41.910.204 T-Piece & Draught Stabiliser & Condensation Trap (except SB60)
98.085.104 T-Piece & Draught Stabiliser & Condensation Trap (SB60)
41.910.221 Wall Band for 200mm Flue Stack (locate at 3m centres)
41.910.206 Guy Wire bracket 200mm
41.910.207 Angled Roof Flashing 200mm – Sheet Aluminium
41.910.208 Flat Roof Flashing 200mm – Sheet Aluminium
41.910.209 Storm Collar 200mm
   
Waste Oil Heaters Extras
   
40.000.238 Draught Stabiliser (supplied with T-Piece assembly)
41.900.868 Silicone Rubber Flexible Roof Flashing 150mm
98.085.497 Silicone Rubber Flexible Roof Flashing 200mm
41.900.869 Silicone Rubber Fixing Kit for Flashing


SB Range Used Oil Heaters Dimentions

Waste Oil Heaters OVERALL DIMENSIONS (mm)

Waste Oil Heaters TECHNICAL INFORMATION

MODEL

WIDTH

LENGTH

HEIGHT

MODEL

HEAT OUTPUT

NETT MAX

(BTU/HR)

HEATED AIR

FLOW

(M3/HR)

ELECTRIC

SUPPLY

(VOLTS)

POWER

CONSUMPTION

(KW)

DAY TANK

CAPACITY

(LITRES)

APPROX FUEL

CONSUMPTION

(LITRES/HR)

SB40

690

1860

1850

SB40

140,000

3200

230

1,1

80

4.5

SB60

690

1860

1850

SB60

180,000

4100

230

1,4

80

6.0

SB80

900

2060

2175

SB80

270,000

6200

400 + 0

1,8

130

9.0

SB110

900

2060

2175

SB110

390,000

8100

400 + 0

2,2

130

12.8


Model

A

B

C

D

E

F

G

H

I

L

N

Q

R

DIA

WEIGHT

KG

 

SB40/60

 

 

570

 

910

 

1425

 

400

 

270

 

 

560

 

120

 

1255

 

805

 

550

 

25

 

400

 

405

 

160

 

180

 

SB80/110

 

 

760

 

1110

 

1750

 

400

 

320

 

760

 

140

 

1525

 

945

 

550

 

25

 

400

 

405

 

180

 

290


Accessories

Flowmatic:

An automatic motor and pump system to keep the “Day oil tank” supplied from a bulk storage tank (pipework and electric cable not included). Maximum distance 25 metres.

For longer distances a pneumatic pump system is available to special order.

Thermostat/Timer ECO.X TFP2

An energy management computer specifically designed for total space heating control.

Features of the ECO.X TFP2

•  Quartz accuracy

•  7 day temperature control with each day having independent settings

•  Two timed periods available for each day

•  Two line LCD giving clear indication of the time, settings, temperature, etc.

Filter Kits

Air inlet filter are available for the main ventilator fan.

 

For Further information on our Sb Range - Automatic Ignition, or any Waste Oil Heaters please contact us.