VAL Infra-red radiant oil fired
![]() |
![]() |
![]() |
| VAL with fuel level indicator, (except VAL 6 KB). |
Vertical inclining with locking mechanism. |
Folding push bar VAL MIDI. |
WORKING PRINCIPLE
1. 45° Vertical inclination infra-red heat screen.
2. High pressure burner.
3. Tank for 10 hours burning duration, (VAL 6 EPX 20 hours burning duration (low) and 15 hours burning duration (high), VAL 6 KB 16 hours burning duration).

• Almost odourless without air flow.
• Fixed radiation temperature circa 150°C at 70 cm (20°C at 3 m).
• Spot heating (and limited space heating).
ADVANTAGES
• Odourless.
• Personal (and limited space) heating.
• No air flow.
FEATURES
• High pressure burner with 15 sec. prepurge control system and 180 sec. postpurge.
• Photocell flame control.
• Combustion chamber of fibre ceramic.
• Thermostat operation is possible.
• 230V/50Hz connection.
• Room ventilation is required.
• Mobile framework. (DAYSTAR portable).
• VAL EPX with oversized tank for 20 burning hours (low) and 15 burning hours (high).
• VAL EPX equipped with overvoltage detector, integrated thermostat en larger radiation disc for 20% further en wider radiation.
• VAL 6-1 STEP and VAL 6-2 STEP may be inclined both vertically as well as horizontally.
• VAL 6-2 STEP with a 2 step burner.
• VAL 6 KB with oversized tank for 16 burning hours.
• Oil preheating set VAL 6 (optional)

APPLICATIONS
Agriculture - Spot heating in large sheds.
Building industry - Spot heating on work sites.
Horticulture - Spot heating in work areas.
Industry - Spot heating in workshops, transit sheds and warehouses.
Industry - Warming up and defrosting machines.
TECHNICAL SPECIFICATIONS | DIMENSIONS AND WEIGHTS
1 kW = 860 Kcal/hr 1 kW = 3413 Btu/hr 1 kW = 3,6 Mj/hr 1 Kg = 1,2 l/hr
|
Model |
Heat |
Fuel consumption oil max. (l/hr) |
Tank capacity (l)
|
Power consumption 230V (AMPS) |
Item |
|
VAL 6-1 STEP |
40
|
3,7
|
40
|
0,25
|
40.106.200
|
VAL 6-2 STEP |
40
|
3,7
|
40
|
0,25
|
40.106.000
|
VAL 6 EPX |
40
|
3,7
|
58
|
0,25
|
41.404.000
|
VAL 6 KB |
40
|
3,7
|
60
|
0,25
|
40.106.100
|
VAL MIDI |
33
|
3,1
|
35
|
0,25
|
40.106.050
|
VAL DAYSTAR |
15
|
1,4
|
10
|
0,5
|
40.106.030
|
|
Dimensions heater only (cm) |
Dimensions including packing (cm) | ||||||||||
|
|
A |
B
|
C
|
D
|
E
|
F
|
KG
|
L | B | H | KG | |
| VAL 6-1 STEP* | 120 |
62
|
93
|
-
|
-
|
-
|
53
|
71 | 65 | 72 | - | |
| VAL 6-2 STEP* | 120 |
62
|
93
|
-
|
-
|
-
|
53
|
87 | 62 | 42 | 63 | |
| 42 | 42 | 32 | - | |||||||||
| VAL 6 EPX | 124 |
65
|
97
|
-
|
-
|
-
|
50
|
71 | 95 | 102 | 59 | |
| VAL 6 KB | 91 |
69
|
91
|
-
|
-
|
-
|
57
|
70 | 66 | 93 | 61 | |
| VAL MIDI | 71 | 66 |
81 |
- |
- |
- |
38 |
96 | 67 | 93 | 43 | |
| VAL DAYSTAR | mm |
58
|
31
|
59
|
-
|
-
|
17
|
- | - | - | - | |
*VAL 6-2 STEP and VAL 6-1 STEP components are packed in 3 boxes
For Further information on our VAL Infra-red radiant oil fired, or any similar products please contact us.