DIRECT OIL FIRED WITH LARGE AIR THROW TAS 800
Features:
- Electric switch components in full lumidity and dust proof control panel (IP54)
- With burner relay, photocell flame control and thermostat connection
- High pressure pump with 2-way pipe system for connection to bulb tank (max. length 50m/height 3m, depends on diameter of pipe)
- Room ventilation is required
- Heat output 325,000 Btu/hr suitable for horticulture and poultry houses
OIL FIRED WITH FLUE CONNECTION ITA/ITAS
Features:
- With burner relay, photocell flame control, overheat protection and thermostat connection
- ITAS models without fuel tank and wheel set, with hooks for suspension and return type fuel pump to be connected to suction and return fuel hose
- High pressure pump with 1-way pipe system. Conversion kit to 2-way pipe system available for connection to bulk tank (max. length 50m/height 3m, depends on diameter of pipe)
- Room ventialtion is required
- 6 models available with heat outputs from 76,000 to 220,000 Btu/hr
OIL FIRED WITH FLUE CONNECTION AND SEPERATE EXTERNAL BURNER IMA
Features:
- With overheating protection and temperature limitation of warm air
- Preheating of chamber, so that no cold air is blown during start up
- Fully automatic, controllable with thermostat connection
- Fuel filter with condensate separator
- Tigerloop can be supplied to change fuel supply from 2-pipe to 1-pipe system
- Burner with rain cover and lower tray for oil containment during servicing
- Room ventilation is required, fresh air connection available
- 7 models available with heat outputs from 208,000 to 584,000 Btu/hr
OIL FIRED WITH FLUE CONNECTION (CONTAINERISED) IMAC
Features:
- Standard with stainless steel frame on box girders with fork truck slots and lifting hooks
- Plate work with stainless steel security screws and durable phosphated body panels with powder coating. E model with stainless steel panels
- Lockable door panels for control box and burner area with feed through glands for cable and fuel hoses
- M.A.N. industrial burner with oil pre-heating and flow control
- Completely automatic burner control with thermostat connection
- With overheat protection and temperature limitation of warm air
- Burner fan and thermal security resettable from control box
- Control box standard with soft-starter, automatic phase reverser, hour counter and 5 resettable fuses. Earth leakage switch and transformer for 0 are available
- Removable outlet flanges Ø 600mm (recirculation hose flange available as accessory)
- Multi-functional warm air distribution head for 2 to 8 hoses available
- Heat output 584,000 Btu/hr
DIRECT PROPANE FIRED VERTICAL GA V FOR CROP DRYING 
Features:
- GA V models with suspension hooks
- E models with quick release gas hose and gas pressure regulator mounted on heater
- Technical specifications as per GA models. For vertical operation the magnetic valve system is altered to suit
DIRECT NATURAL GAS FIRED AGA MODULATING MODEL AGA 102 DUAL FUEL MODEL PROPANE/NATURAL GAS AGA 111
Features:
- Low NOX burner with electronic ignition, ionisation protection and thermostat connection
- Models with separate fresh air intake to the burner do not require room ventilation
- CE-GASTEC approved
- Available in 4 models (also in stainless steel)
- All models can be used horizontally and vertically, blowing either upwards or downwards
- Heat outputs from 136,000 to 448,000 Btu/hr
MODULAR ASSEMBLY UNITS WITH FLUE CONNECTION AND SEPARATE EXTERNAL OIL OR GAS BURNER ISA
Features:
- Exterior cover phosphated with powder coating suitable to the glass house climate, interior cover made of special steel to minimize radiation losses
- Automatic burner and fan control. With overheat protection, temperature limitation of warm air, after cooling thermostat and thermostat connection
- No cold air is blown during start up
- Easy access for cleaning
- With suspension hooks, installation of flue on either side. Vertical positioning possible, blowing either upwards or downwards
- Room ventialtion is required, fresh air intake available
- Heat outputs from 200,000 to 412,000 Btu/hr
INFRA-RED RADIANT OIL FIRED VAL
Features:
- Mobile framework, model VAL 6-2 STEP has a rotaional screen
- High pressure burner with 15 sec. prepurge control system and 180 sec. postpurge. Photocell flame control. VAL 6-2 STEP with 2 stage nozzle burner.
- Combustion chamber of fibre ceramic
- Thermostat operation is possible
- 230V/50Hz connection
- Room ventilation is required
FREE STANDING CABINET WARM AIR HEATERS
Features:
- Innovative design techniques and proven heat exchange technology to produce units which are cost effective, efficient and aesthetically pleasing
- Gas or oil fired
- Large volume combustion chamber for maximum heat transfer
- Virtually weld-free heat exchanger eliminates possibility of weld failure
- Combustion chamber/heat exchanger assembly is flexibly mounted to allow for thermal expansion
- Double skin construction - air cooled heat shield keeps outer casing cool
- Time switch and thermostats are pre-wired to heater to reduce installation costs
- Slide in panels - easily removed for faster servicing
- 10 model sizes cover heat outputs from 100,000 Btu/hr to 1,000,000 Btu/hr (29kW to 293kW) and are available as free standing vertical units or, alternatively, as horizontal or inverted units
|